Measurement Capability

Parameter / Test Range / Accuracy / Specifications
Dry Heat Test / Cold Test/ Thermal cyclic test -70 °C to + 180 °C (± 2°C)
Rate of Rise Fall Up to 5 °C / minute
Damp Heat Cyclic-
Damp Heat Steady state - 20 °C to 90 °C (± 2°C) with 20 % to 98 % RH (± 3%)
Rate of Rise Fall Up to 2 °C/ minute
Thermal Shock -70°C to + 195°C
Three Zone/ Transfer time < 1 min
Salt Mist /Corrosion Solution as per international standards
Vibration a. Sinusoidal b. Random - 1 Ton force, 5 Hz to 2 kHz
Displacement ± 20 mm/ 30g
Drop & Topple As per standards requirements
Electrical tests Insulation Resistance up to 1kV
Breakdown Test Up to 5 kV AC

List of Major Facility

Facility / Equipment / Tools Make and Model

Major Products Tested / Project Done

Major Products Tested / Projects Done